Advanced, yet still at a favourable price, equipped with up to 9 electrochemical and NDIR sensors. Has a built-in pressure sensor, large internal memory for results and built-in ribbon printer for standard (non-thermal) paper. Optional condensation "miniDryer" completes the offer for our best-selling portable device.

Brochure

Features

  • Produced in two kinds of casing: soft and hard
  • Equipped with up to 7 electrochemical cells
  • Equipped with up to 2 NDIR sensors
  • Built-in 58mm ribbon graphic printer
  • Built-in rechargeable battery for up to 8 hours of operating
  • Peltier "miniDryer" with a peristaltic pump for condensate removal (optional)
  • Probe holder with a standard M30x1 fitting, fits all madur gas probes with the K-type thermocouples
  • Gas filter with condensate trap and replaceable insert
  • Differential pressure sensor - for measurements of chimney draft and flow velocity (with help of Pitot tube)
  • Soot measurement program
  • Measurements of gas and ambient temperatures
  • 2 additional inputs for extra temperature sensors
  • Analogue outputs (0/4-20mA) - optional
  • Built-in large memory for results, two formats of data savings
  • Calculations of many additional parameters
  • Firmware for gas calibrations

Two versions of analyser are available:

  1. Version in "soft" casing
  2. Version in "hard" casing

Tech specs

General Parematers - Version A (in soft casing)
Dimensions (W x H x D) 243 x 130 x 60mm
257 x 130 x 60mm (with gas connectors)
Weight 6.2 ÷ 7.2kg
Casing material Textile (polyester)
Operating conditions T: 10°C ÷ 50°C, RH: 5% ÷ 90% (non-condensing)
Storing temperature 0°C ÷ +55°C
Power supply: input | max power consumption 90 ÷ 240VAC | 70W
Battery: type | work time | charging time Lead-acid, rechargeable 12V / 2.2Ah | 7h | 14h
Data memory: size | number of results 32kB | 30 reports + 10 banks (1024 sets of data)
Display Graphical LCD 128x128, with variable contrast and backlighting
Printer High-speed dot matrix, graphic printer for 57mm normal paper
Analogue outputs Two current (0/4mA ÷ 20mA)
Gas pump | gas flow Diaphragm, max 2l/min (with automatic flow control) | 90l/h (1.5l/min)
Purging pump for CO sensor (optional) Diaphragm, max 1.5l/min
Communication interface with PC computer RS-232C
Gas filtering
  • In-line filter included in the gas probe hose
  • Built-in input filter with water-trap and replaceable insert

General Parematers - Version B (in hard casing)
Dimensions (W x H x D) 455 x 270 x 220mm
Weight (without accessories) 8.2 ÷ 9.2kg
Casing material Wood & aluminium
Operating conditions T: 10°C ÷ 50°C, RH: 5% ÷ 90% (non-condensing)
Storing temperature 0°C ÷ +55°C
Power supply: input | max power consumption 90 ÷ 240VAC | 70W
Battery: type | work time | charging time Lead-acid, rechargeable 12V / 2.2Ah | 7h | 14h
Data memory: size | number of results 32kB | 30 reports + 10 banks (1024 sets of data)
Display Graphical LCD 128x128, with variable contrast and backlighting
Printer High-speed dot matrix, graphic printer for 57mm normal paper
Analogue outputs Two current (0/4mA ÷ 20mA)
Gas pump | gas flow Diaphragm, max 2l/min (with automatic flow control) | 90l/h (1.5l/min)
Purging pump for CO sensor (optional) Diaphragm, max 1.5l/min
Communication interface with PC computer RS-232C
Gas filtering
  • In-line filter included in the gas probe hose
  • Built-in input filter with water-trap and replaceable insert

Minidryer (optional)
Dimensions (W x H x D) 24 x 120 x 124mm
Weight 800g
Operating conditions T: 10°C ÷ 50°C, RH: 5% ÷ 90% (non-condensing)
Storing temperature -20°C ÷ +55°C
Power supply: input | max power consumption 15V DC (from analyzer's “Probe” socket) | 10W
Drying method Water condensation by rapid cooling down
Cooler type Based on Peltier element
Cooling temperature Down to +4°C electronically stabilised / Dew point of outlet gas at least 8°C below the ambient air temperature
Maximum gas flow for efficient drying 90l/h
Condensate pump Peristaltic, 38 ml/min.

Measurements of gas components
The analyser can be equipped with sensors from below list

O2 – (EC, PP) 20.95%, 25%, 100%
CO – (EC) 20 000ppm, 10%
CO – (EC, H2 comp) 2000ppm
CO – (NDIR) 10%, 50%, 100%
CO2 – (NDIR) 25%, 50%, 100%
CxHy – (NDIR) 5%, 25%, 100%
NO – (EC) 5000ppm
NO2 – (EC) 1000ppm
SO2 – (EC) 5000ppm
H2S – (EC) 1000ppm
H2 – (EC) 2000ppm, 20 000ppm
NH3 – (EC) 1000ppm
CL2 – (EC) 250ppm
HCl – (EC) 50ppm
CL2 - (EC) 250ppm
HCl - (EC) 50ppm

EC - Electrochemical sensor
PP – partial pressure
NDIR – non dispersive Infrared sensor

Other measurements / calculated results
Method Range
Tgas – gas temperature K-type thermocouple -10 ÷ 1000°C | 0.1°C
S-type thermocouple -10 ÷ 1500°C | 0.1°C
Tamb – gas temperature PT500 resistive sensor -10 ÷ 100°C | 0.1°C
PT500 resistive sensor
T1 – external temperature K-type thermocouple -10 ÷ 1000°C | 0.1°C
S-type thermocouple -10 ÷ 1500°C | 0.1°C
T2 – external temperature PT500 resistive sensor -10 ÷ 100°C | 0.1°C
K-type thermocouple 10 ÷ 100°C | 0.1°C
T3 – external temperature K-type thermocouple -10 ÷ 1000°C | 0.1°C
S-type thermocouple -10 ÷ 1500°C | 0.1°C
T4 – external temperature PT500 resistive sensor -10 ÷ 100°C | 0.1°C
Differential pressure Silicon piezoresistive pressure sensor -25hPa ÷ +25hPa | 10Pa (0.01hPa)
Gas flow velocity Indirect, with Pitot tube & pressure sensor 1 ÷ 50m/s | 0.1m/s
Lambda λ – excess air number Calculated 1 ÷ 10 | 0.01
qA – stack loss Calculated 0 ÷ 100% | 0.1%
Eta η – combustion efficiency Calculated 0 ÷ 120% | 0.1%
U1÷U2 – external analogue input (voltage) Delta-sigma ADC -20V ÷ +20V | 0.01V
I1÷I2 – external analogue input (current) Delta-sigma ADC -20mA ÷ +20mA | 0.01mA

Drawings

Drawing #1
Sensonic 4000 filter can be fitted with inserts of different diameters: Insert of 15mm inside diameter is fitted with help of filter insert guide. For 12mm insert, the guide must be removed, and insert is installed directly in the filters's head.
Drawing #2
Gas fitting - quick coupler, male part (615A0203A)
Drawing #3
Gas fitting - quick coupler, male part (615A0203A)
Drawing #4
“Probe” connector, Binder 680 series, 7-pin female (512O0710C)
Drawing #5
“Temp1” & “Temp2” connectors, Binder 712 series, 3-pin female (512M0310C)
Drawing #6
“RS-232C” connector, Binder 712 series, 4-pin female (512M0410C)
Drawing #7
“U/I1” & “U/I2” connectors, Binder 712 series, 5-pin female (512M0510C)
Drawing #8
Dimensions of the A version of analyzers - in “soft” casing
Drawing #9
Dimensions of the B version of analyzers - in “hard” casing
Drawing #10
View at the analyser's front panel (keyboard and display)

Equipment

Analyser's standard equipment supplied along with the device
  • 3m mains cable (type of plug to be selected)
  • Comparison scale with paper filters for the soot test
  • Single gas filter with condensation trap and filter inlet (pore size 5µm)
  • 2.5m RS-232C communication cable with DB9 female connector
  • Software CD with programs and manuals
  • Quick coupler for the probe holder (1pc.)

Supplemental equipment - ordered separately, but essential to work with the analyser
Probe holder
Gas probe pipe

Optional equipment
Ambient temperature sensor
Pitot tube
RS-232C to USB converter
Bluetooth communication module